92 analyses, tests and pilot capabilities with the standard method, typical lead time and where the work happens. Filter by category or show only tests on our ISO 17025 scope.
| Tests & capabilities | 92 |
|---|---|
| Categories | 17 |
| On ISO 17025 scope | 12 |
| Run in MPI’s own lab | 75 |
92 of 92 tests and capabilities
Spectroscopy
-
Fourier Transform Infrared Spectroscopy (FTIR) with ATR
ATR or transmission of a liquid or solid sample
Near-IR and Raman, wide-range Bruker Vertex 80v FTIR
ISO 17025 -
IR Microscopy
IR spectrum and analysis with IR microscope
-
Raman Microscopy
Raman spectroscopy of a microscopic sample, very useful for graphene testing
-
Nuclear Magnetic Resonance (NMR)
Solution and solid state, 80–600 MHz, 4 nuclei systems (1H, 13C, 19F, 31P)
80 & 400 MHz at MPI; other nuclei, 2D, ROSY, COSY, etc.
-
Mass Spectrometry (MS)
See GC/MS and LC/MS
Requires campus involvement
-
Laser Diffraction Infrared Spectroscopy (LDIR)
Analysis of microplastics
-
UV-Vis
Absorbance vs. wavelength, 190–840 nm
Metals & inorganics
-
ICP-OES
Inductively coupled plasma optical emission spectrometry
-
Energy Dispersive X-ray (EDX) Elemental Analysis
Energy dispersive X-ray elemental analysis
Microscopy
-
Scanning Electron Microscopy (SEM) with EDX
Electron microscopy digital imaging; elemental weight percent via EDX
-
Imaging Analysis
Particle size and distribution
-
Keyence VHX 7000 Digital Microscope
Light microscope with digital imaging, depth profiling and 3D capabilities
3D imaging, topography, optical shadow mode, fluorescence, polarizing light, layer and thickness analysis
Rheology & viscosity
-
Viscometry
Intrinsic viscosity using Cannon-Fenske or Ubbelohde viscometers
-
Viscosity (Stormer)
Stormer viscometer
-
Viscosity (Brookfield)
Brookfield DV-I+ viscometer (Pa·s) with spindles 1–7
Other viscometer models and spindles
-
Viscosity (inherent)
Inherent viscosity using Ubbelohde
-
Rheology
Cone and plate or parallel plate
Requires campus involvement
Separations
-
HPLC with RI, UV-Vis and ESI detectors
Identification and separation of chemical components using reverse phase-C18 columns with gradient solvent setup
Solvents include acetonitrile, isopropanol, water and THF. Often requires sample prep or method development.
-
Gel Permeation Chromatography (GPC)
Relative molecular weight determination using polystyrene standards
Requires campus involvement
-
Molecular Weight Distribution / Size Exclusion Chromatography
GPC with absolute molecular weight of a liquid or solid sample soluble in THF
Requires campus involvement
-
Gas Chromatography–Mass Spectrometry (GC/MS)
Gas chromatography with mass spectrometry
Requires campus involvement
-
Liquid Chromatography–Mass Spectrometry (LC/MS)
MS ion trap LC
Requires campus involvement
Particle size
-
Particle Size Analysis, wet/dry
Particle size of a liquid or powder sample and/or zeta potential
In water, in solvent or dry; zeta potential
-
SEM or Light Microscopy Particle Size Analysis
Digital imaging and analysis
Thermal analysis
-
Differential Scanning Calorimetry (DSC)
Melt temperature and/or glass transition temperature of a solid (modulated DSC available)
Modulated DSC, nitrogen or oxygen environments, multiple pan selections
ISO 17025 -
Thermogravimetric Analysis (TGA)
Degradation temperature and residual ash content
E1131, TGA-MS and TGA-IR
ISO 17025 -
Dynamic Mechanical Analysis (DMA)
Temperature ramp at set frequency using cantilever beam
D5023, D5024, D5026, D5418, D7028, E1640
ISO 17025 -
Thermomechanical Analysis (TMA)
Coefficient of linear thermal expansion
E1545, E1824, E2347
ISO 17025
Wet chemistry
-
Titrations
Titration for OH or acid number in duplicate; AV reported in mg KOH/g of sample (depends on solubility)
-
Fractional Distillation
Multi-solvent fractionation
-
Extractions
Grinding and boiling in solvent
-
Dissolutions
Dissolving polymer materials
-
pH
pH meter with probe, calibrated with two standards depending on sample pH
Physical & mechanical
-
Melt Flow (Tinius Olsen Extrusion Plastometer)
Melt density, viscosity, volume rate and flow rate of a pelletized solid
Melt flow of PVC, ASTM D3364
ISO 17025 -
Impact
IZOD or drop impact testing
ISO 17025 -
Physical Testing: plastics, films, fabrics, composites, rubbers
Tensile strength with or without video extensometer, compressive properties, 3-point bend/flexural, tear and peel testing
Also D412, D470, D732, D882, D955, D3846, D3518, D5379, D6252, D6862. Often requires sample prep or method development.
ISO 17025 -
Density and/or Specific Gravity
Specific gravity via water displacement
ISO 17025 -
Residual Ash Content
Residual ash content of plastics or composites
ISO 17025 -
Moisture Absorption
Moisture absorption testing
ISO-accredited for D570
ISO 17025 -
High-speed Puncture / Instrumented Impact
Instrumented impact of panels
Requires campus involvement
-
Abrasion Resistance
Taber abrasion
D3389 for fabrics
-
Hardness Testing
Shore A and D hardness
-
Coefficient of Friction (CoF)
Sample on sled across aluminum
Coatings
-
Minimum Film Formation Temperature (MFFT)
Film formation from a liquid sample
-
Colorimetry
CIE L*a*b* color measurements; yellowness and whiteness index
-
Gloss
Gloss at 20, 60 and 85 degrees; gloss, sheen or flat surface appearance
-
Opacity
Hiding power of coating
-
Coatings Tests
Scrub resistance, pencil hardness, MEK double rubs, Konig hardness and more
D660, D661, D714, D1308, D1544, D2486, D4752, D4828
-
Sag Test
Coatings sag testing
-
Film Thickness
Dry film thickness
-
Density of a Liquid
Weight per gallon cup
-
Constituent Content
Non-volatiles by mass and by volume
-
Oil Absorption of Pigments
By spatula rub-out
Synthesis & formulation
-
Glass Reactors
25 mL to 50 L
-
High-Pressure Stainless Steel Reactors
100 mL to 5 gallons
-
Mixing Vessels
Stainless steel and glass mixing tanks, 50–250 gallons
-
Dual Asymmetric Centrifugal Mixer
Planetary mixing (100 g–1 kg) for rapid development of coating formulations, resin grinds and air-free mixing
-
Overhead Mixing / Stirring
Adjustable speed and torque mixers with a variety of blades to replicate industrial mixing
-
Product Formulation
Coatings and more
-
Contaminant Identification & Deformulation
Chemical identification using multiple pieces of equipment
Extrusion & molding
-
Co-rotating Twin-Screw Extruder, 24 mm (ThermoFisher)
Up to 450 °C; volumetric and gravimetric feed; three top vent ports; solid, liquid and powder feed; three-strand and slit dies; 5 lb minimum batch; up to 1000 RPM
-
Brabender Prep Center Mixing Head
150 RPM, 350 mL capacity, 400 °C max, roller-type mixing blades
-
85-ton Injection Molder
6.04 oz shot size, various ASTM molds, up to 800 °F, up to 250 RPM
-
Formech 686 and 300XQ Thermoforming
Up to 11×19 and 25×25 inch forming with PVC, PETG, PS and more
-
Melt Press
Carver Automated 5492 ASTM hydraulic heated press, 800 °F, 12×12 inch platens, 15 tons
-
Miniature Injection Molding
Capable of using 3D-printed molds
-
Filabot EX2 Mini-Extruder
Single-screw filament extruder with take-up and cooling; 35 RPM, 5/8 in screw, 12 L/D, 450 °C max, 2 lb/hour
CAD & scanning
-
CAD Design
SolidWorks and Fusion 360
-
Laser Scanning
FARO laser and tracker, ±0.0016 in volumetric precision, portable, complex and large components
Additive manufacturing
-
UV-Cure and FDM 3D Printing
Multi-modulus materials, many materials and colors, medium to large format parts, high resolution
Biodegradation
-
Disintegration
Disintegration of plastics under pilot-scale composting conditions; part of the BPI compostable certification scheme
-
Respirometer
Aerobic biodegradation under composting and marine conditions; anaerobic setup with nitrogen available; minimum 200 g sample
ASTM D5338 is part of the BPI testing scheme
-
Ecotoxicity
Effects of a test sample on seedling emergence and early growth
Weathering & degradation
-
QUV Accelerated Weathering
Controlled UVA or UVB range, temperature, irradiance and condensation
Imaging and color change recommended
-
Salt Fog (QFOG)
Corrosion testing in salt spray cabinet
Imaging and color change recommended
-
Xenon-Arc (QSUN)
Cyclic 4 h on at 340 nm, 0.35 W/m², 63 °C, 35% RH with daylight filter, then 1 h off at 40 °C, 35% RH
Imaging and color change recommended
-
Temperature & Humidity Cycling
Sealed 32 ft³ chamber cycling −68 °C to 180 °C and 10–98% RH
-
Temperature Exposure
Programmable forced-convection ovens, 30 °C to 210 °C
-
Corrosion Testing
Potentiodynamic polarization resistance and corrosion rates; corrosion from immersion by mass loss
-
Chemical Degradation (standard or custom)
Soaking, dipping and more with titrations and pH monitoring
Imaging and color change recommended
Other
-
X-ray Diffraction (XRD)
Crystallinity information
-
Electrical Conductivity
In-plane conductivity of a solid sample
-
Thermal Conductivity
Thermal conductivity
-
AFM (incl. Cypher Asylum Research AFM and AFM-IR)
Atomic force microscopy
Requires campus involvement
-
Permeability
Perm cup measurements
-
Specialty Sample Preparation
Cutting, measurements, machining and more
-
Conditioning Materials for Testing
Environmental conditions, temperature, %RH
ISO 17025 -
Cyclic and Fatigue Testing
Requires campus involvement
-
SAXS / WAXS (Xenocs)
X-ray scattering
Requires campus involvement
-
Vapor Sorption Analyzer
Requires campus involvement
-
ThermoScientific ESCALAB Xi+ XPS
X-ray photoelectron spectroscopy
Requires campus involvement
-
Bruker Microflex MALDI-ToF with PSD
Requires campus involvement
No match. MPI regularly adds methods and builds custom tests, so ask us about it.
Lead times are typical and subject to change.
“USM campus” tests use instruments in the School of Polymer Science & Engineering. Many physical tests and HPLC work need sample prep or method development first. Don’t see your method? We add new ones often.
- Call
- 601.266.4607
- Visit
- 46 Shelby Thames Drive, Hattiesburg, MS
- Hours
- Mon–Fri, 8 AM–5 PM CT